![~v1Z - 70C](/images/new-backgrounds/123500/12350053x1.webp)
~v1Z - 70C
2-4. Abnonnal increase of output ripple
In case irregular increase is seen for the output ripple like the one below, it needs to replace C22 and C23 with new ones because they have been fatigued.
- | t |
100mV or less | |
t | |
(Normal rippla) |
Input: AC220 - 240V
Output: 5V,3.75A
Usa oscilloscope
Several hundreds millivolts
(Abnormal ripple)
26