Initialization (Reset)/Functional Restriction Setting (FUNCTION)

You can return the settings to their factory-preset values and restrict operations.

1.Press SIZE until “F” is displayed in the upper left area of the screen, then while “F” is being displayed, press , , , and in that order.

FUNCTION

1/1

 

 

 

 

ALL RESET

 

 

 

ADJUSTMENT LOCK

OFF

 

ADJUSTMENT LOCK TARGET

 

 

RS-232C

UNLOCKED

 

OSD DISPLAY

ON1

 

LED

ON

 

TEMPERATURE ALERT

LED

 

STATUS ALERT

OFF

 

POWER BUTTON

MONITOR

 

CONTROLLER INPUT

 

END[MENU]

2. Select and set the items.

ALL RESET

Resets the settings to the factory default settings.

Press , select ALL RESET, and then press MENU .

After initialization, turn the main power switch off and then back on.

When the PN-ZB01 (optional) is attached, press ,

select the resetting method, and then press MENU .

ALL RESET1 ....Resets all the settings to the factory

default settings.

ALL RESET2 ....Returns all settings to the factory default

settings except for the following items: LAN SETUP, RS-232C/LAN SELECT, ID No. SET, BAUD RATE, NETWORK, MAIL, SERVICE & SUPPORT, and SNMP (See page 24, and pages 48 to 51.)

ADJUSTMENT LOCK

You can disable operations on the monitor and the remote control unit that use buttons.

OFF ...Enables operation.

ON 1 ..Disables all operations other than turning power on/off and FUNCTION.

ON 2 ..Only the FUNCTION operations are enabled. Disables all operations other than FUNCTION (not even power on/off).

ADJUSTMENT LOCK TARGET

Sets the target to prohibit operation of with

ADJUSTMENT LOCK.

REMOTE CONTROL....

Prohibits remote control operation

MONITOR BUTTONS....

Prohibits monitor switch operation

BOTH

Prohibits remote control and

 

monitor switch operation

RS-232C

(RS-232C/LAN when the PN-ZB01 (optional) is attached)

Specifies whether to allow control via RS-232C or LAN (see pages 31 and 44).

OSD DISPLAY

Shows/hides the menu, modes, and messages. The FUNCTION screen cannot be hidden.

ON 1

Shows all menus, modes and messages.

ON 2

Hides messages automatically displayed

 

by the display. Shows messages during

 

operation.

OFF

Hides all menus, modes, and messages.

LED

Specifies whether to light the power LED.

OFF cannot be selected when STANDBY MODE is LOW POWER.

TEMPERATURE ALERT

Selects the notification method for an abnormal temperature.

OFF

Do not notify about an abnormal

 

temperature.

OSD & LED ..

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately and the screen

 

displays a message: TEMPERATURE.

LED

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately.

STATUS ALERT

Selects the notification method for a hardware error.

OFF

Do not notify about the error.

OSD & LED ..

When a hardware error is detected, the

 

power LED flashes in red and the screen

 

displays a message: STATUS [xxxx].

LED

When a hardware error is detected, the

 

power LED flashes in red.

POWER BUTTON

Normally, leave this setting as MONITOR.

When using an optional part, if instruction appears, change the setting accordingly.

CONTROLLER INPUT

Normally, you do not need to change this setting. When using an optional part, if instruction appears, change the setting accordingly.

3. Press MENU to return to the normal screen.

TIPS

When both abnormal temperature and hardware error are detected, the hardware error notification overrides.

If TEMPERATURE ALERT or STATUS ALERT is set to OSD&LED, alert messages will appear even if the OSD DISPLAY is set to ON 2 or OFF.

E30