TEST PROCEDURES
PROCEDURE
COMPONENT TEST
LETTER
KMAGNETRON THERMISTOR TEST
CARRY OUT 3D CHECKS.
Disconnect
Room Temp. | Resistance |
15˚C | Approx. 15.91 kΩ |
20˚C | Approx. 13.04 kΩ |
25˚C | Approx. 10.74 kΩ |
If the meter does not indicate above resistance, replace the thermistor.
CARRY OUT 4R CHECKS.
EXHAUST THERMISTOR TEST
CARRY OUT 3D CHECKS.
Disconnect
Room Temp. | Resistance |
15˚C | Approx. 77.45 kΩ |
20˚C | Approx. 61.47 kΩ |
25˚C | Approx. 49.12 kΩ |
If the meter does not indicate above resistance, replace the thermistor.
CARRY OUT 4R CHECKS.
INTAKE THERMISTOR TEST
CARRY OUT 3D CHECKS.
Disconnect
Room Temp. | Resistance |
15˚C | Approx. 15.88 kΩ |
20˚C | Approx. 13.03 kΩ |
25˚C | Approx. 10.74 kΩ |
If the meter does not indicate above resistance, replace the thermistor.
CARRY OUT 4R CHECKS.
LMOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals.
Resistance of Blower motor should be approximately 52Ω.
Resistance of Stirrer motor should be approximately 8.8 kΩ.
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
MNOISE FILTER TEST CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of noise filter. Using an ohmmeter, check between the terminals as described in the following table.