Flow Chart of Troubleshooting

9-14. PCS Receiver

RX ON

Cell Power : -60dBm

Yes

MODULE100 Pin13≥

-65dBm

Yes

MODULE100 5,6

-68dBm

Yes

U100

pin G7 ≥ -70dBm pin F7 ≥ -70dBm

Yes

No

No

No

Resolder

MODULE100,C102,L102

No

Check MODULE100

pin9,pin11 = L

Yes

Resolder L101,L100,L103

Check ANT Switch

control circuit

Resolder MODULE100

U100 pin

No

U100 pin

No

Check & Resolder

C2,B1,B2,A1

≥ 0.2Vp_p

Yes

G4,F3,D6,C5,B3,A5, F1 29,32,33,36 ≥ 2.8V

pin C1 ≥2.9V

C115,C116,C117,C114

And PMU Part

Check UCP200

END

Yes

Resolder U100

9-26

SAMSUNG Proprietary-Contents may change without notice

This Document can not be used without Samsung's authorization

Page 54
Image 54
Sharp SGH-F250 manual PCS Receiver