RS-232C Specifications and Commands
Computer controlA computer can be used to control the projector by connecting an
Set the serial port settings of the computer to match that of the table.
Signal format: Conforms to | Parity bit: None |
Baud rate*: 9,600 bps / 38,400 bps / 115,200 bps | Stop bit: 1 bit |
Data length: 8 bits | Flow control: None |
*Set the projector’s baud rate to the same rate as used by the computer.
Basic formatCommands from the computer are sent in the following order: command, parameter, and return code. After the projector processes the command from the computer, it sends a response code to the computer.
Command format
| C1 C2 | C3 | C4 | P1 | P2 | P3 | P4 |
|
|
|
|
| Return code (0DH) |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Response code format | Command | Parameter |
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Normal response |
| Problem response (communication error or incorrect command) | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| O | K |
|
| Return code (0DH) |
|
|
| E | R | R |
| Return code (0DH) |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Info
•When you have more than one command to give to the projector, send each of them only after the re- sponse code for the previous one is received.
•“POWR????”, “TABN _ _ _ 1”, “TLPS _ _ _ 1”, “TLPS _ _ _ 2”, “TPOW _ _ _ 1”, “TLPN _ _ _ 1”, “TLTT _ _ _ 1”, “TLTT _ _ _ 2”, “TLTM _ _ _ 1”, “TLTM _ _ _ 2”, “TLTL _ _ _ 1”, “TLTL _ _ _ 2”, “TNAM _ _ _ 1”, “MNRD _ _ _ 1”, “SNRD _ _ _ 1”, “PJN0 _ _ _ 1”
−When the projector receives the special commands shown above :
*The
*The “Auto Power Off” timer will not be reset.
−The special commands are available for applications that require continuous polling.
(Do not repeatedly or periodically send any commands other than these special commands in STANDBY mode as it will cause problems.)
Note
•When controlling the projector using the
•If an underbar (_) appears in the parameter column, enter a space.
•If an asterisk (*) appears in the parameter column, enter a value in the range indicated in brackets under Control Contents.
PJLinkTM Compliant:
This product conforms with the PJLink standard Class 1 and all Class 1 commands are implemented. This product confirms with the PJLink standard specification version 1.00.
For additional information, visit “http://pjlink.jbmia.or.jp/english/”.
-14