Shindaiwa 81359 manual hour Maintenance, Every 135 hours of operation

Models: 81359

1 40
Download 40 pages 60.34 Kb
Page 16
Image 16
135-hour Maintenance

135-hour Maintenance

Every 135 hours of operation,

remove and clean the muffler.

WARNING!

Never operate this trimmer with a damaged or missing muffler or spark arrester! Operating with missing or damaged exhaust components is a fire hazard, and can also damage your hearing!

1.Remove the spark plug boot.

2.With a 3 mm hex wrench remove the 1 muffler cover and 3 engine cover screws and the engine cover. See Figure 30.

3.With a Phillips type screwdriver remove the 5 screws holding the spark arrester screen and cover to the muffler. See Figure 30.

4.Remove the screen and clean it with a stiff bristle brush.

5.With a 4 mm hex wrench remove the 3 muffler bolts and the muffler.

See Figure 30.

6.Inspect the cylinder exhaust port for any carbon buildup.

7.Gently tap the muffler on a wood surface to dislodge any loose carbon.

Engine Cover

Engine

 

 

 

Cover

 

 

 

Screws

 

 

 

 

 

 

 

 

 

Muffler

 

 

 

 

Cover

 

 

 

 

Muffler

 

 

 

Cover Screw

 

 

 

 

Muffler

 

 

 

Muffler

Screws

 

 

 

 

 

 

 

Gasket

Screws

 

 

 

 

 

Muffler

Spark Arrester

Spark Arrester

Outlet

 

Gasket

Screen

Cover

 

Figure 30

 

 

 

 

 

8. Reassemble the spark arrester, muffler

IMPORTANT!

If you note excessive carbon buildup, consult

and engine cover in the reverse order of

disassembly.

with an authorized Shindaiwa servicing

 

dealer.

 

 

 