This quick start manual is only intended for use by professional installers who have an adequate working knowledge of video systems!
This manual outlines the most important information about the SIMATRIX NEO Alarm box. It is, however, vital that you also refer to the detailed information in the full operating instruction of SIMATRIX NEO.
Installation and set-up
Step 1: Provisionally connect the SIMATRIX NEO to the electrical supply
Required power supply: TN network (to VDE 0100, section 300 or EN 60950)
Voltage range: 110 - 240 Volt
Once the system has been connected to the electrical supply, and assuming the device is in good operating the LED at the front of the unit will lit.
To continue installation, you must now unplug all NEO components at the mains!
Step 2: establish SysLink-connection
Use the marked
Step 3: setup device adress
First alarm box must be set to device address „2“, the second alarm box must be set to address „3“.
Step 4: set config-switch
In case the alarm box is the last device on
Step 5: change alarm base parameters
Control software: Alarm base parameters button
Alarm sensor settings
Step 6: Alarm sensor to camera allocation
Control software: Sensors / Camera groups button
Step 7: Further programming
If applicable, enter further parameters in order to tailor the function of the SIMATRIX NEO to suit individual operating needs and the rest of the system.
Step 8: Make a
Operation and storage
Do not operate or store the unit in following locations:
•Extremely hot or cold places
•Close to sources of strong magnetism
•Close to sources of powerful electromagnetic radiation such as radios or TV transmitters.
•In humid or excessively dusty places
•Where exposed to mechanical vibrations.
Care and maintenance
The alarm box is
Use a clean soft piece of cloth to wipe small amounts of dirt or dust from the body.
Specifications
Alarm Inputs: | 128 Alarm Inputs, (4 x 32 Inputs) |
Input resistance: | 2,2 Kilo Ohm |
Threshold: | 2,5 V DC |
Max. voltage: | internal |
Alarm pulse: | min. 300 milliseconds |
Length | max. 10 m |
Connection Alarm: | 4 x |
Controller | 1 |
Interface | SysLink |
Power requirement | 115 / 230 VAC (+10% / |
| (internal switchable) |
Fuse | 2 x 125 mA slow |
Power consumption | 3 VA |
Operating temperature | + 5 °C to 45 °C |
Relative humidity | 30 to 85 %, non condensing |
Construction: | 19 inch chassis, 1 HU |
Dimensions (W x H x D): | 449 x 44 x 206 mm (without 19” mount) |
© 2005 Siemens Building Technologies: Fire and Security Products
Data and design subject to change without notice