6.4 Parameter of configuration file SYS_PAR.INI

The configuration file SYS_PAR.INI includes the parameter for inverting of the DIO- In/Outputs.

If the file SYS_PAR.INI is not present, the operation system uses the default settings from file SYS_PAR.DEF.

Parameter

DIO_MASKE_EIN=xxx

000: Inputs not negated

 

 

 

255: Inputs negated

Parameter

DIO_MASKE_AUS=xxx

000: Outputs not negated

 

 

 

255: Outputs negated

___________________________________________

# System parameters 10.05.96

 

 

[ID = 99999999

Note: Your Bridge serial number

#DIO settings all inputs and outputs inverted [DIO

DIO_MASKE_EIN =255 DIO_MASKE_AUS =255 [SCHL

S 0000 1111 2222 3333

#End