MTX-H15 UMTS-HSDPA terminal modem

http://www.matrix.es

Parameter

IBATT+

IBATT+

IVUSB

Description

OFF State supply current

Average GSM / GPRS supply current1

Peak current dur- ing GSM transmit burst

Average WCDMA supply current

USB transceiver supply current (average)

Conditions

 

Min

 

Typ

 

Max

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER DOWN

 

 

 

50

 

 

 

μA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=9

 

 

 

2.92

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=5

 

 

 

3.42

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=2

 

 

 

5.62

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDLE (USB active) @DRX=2

 

 

 

552

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voice Call GSM900; PCL=5

 

 

 

350

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPRS Data transfer GSM900; PCL=5; 1Tx/4Rx

 

 

 

375

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPRS Data transfer GSM900; PCL=5; 2Tx/3Rx

 

 

 

540

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDGE Data transfer GSM900; PCL=5; 1Tx/4Rx

 

 

 

315

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDGE Data transfer GSM900; PCL=5; 2Tx/3Rx

 

 

 

410

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voice Call GSM1800; PCL=0

 

 

 

315

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPRS Data transfer GSM1800; PCL=0; 1Tx/4Rx

 

 

 

325

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPRS Data transfer GSM1800; PCL=0; 2Tx/3Rx

 

 

 

430

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDGE Data transfer GSM1800; PCL=0; 1Tx/4Rx

 

 

 

290

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDGE Data transfer GSM1800; PCL=0; 2Tx/3Rx

 

 

 

355

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOICE Call GSM900; PCL=5

 

 

 

1.81

 

2.93

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOICE Call GSM1800; PCL=0

 

 

 

1.51

 

2.13

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=9

 

 

 

2.62

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=8

 

 

 

3.02

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP (USB Suspend) @DRX=6

 

 

 

5.32

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle (USB active) @ DRX=6

 

 

 

452

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UMTS Data transfer Band I @+10dBm

 

 

 

390

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HSDPA Data transfer Band I @+10dBm

 

 

 

450

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UMTS Data transfer Band I @+23dBm

 

 

 

750

 

8203

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HSDPA Data transfer Band I @+23dBm

 

 

 

775

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB suspend

 

 

 

0.5

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB active

 

 

 

3

 

 

 

mA

 

 

 

 

 

 

 

 

 

1.With an impedance of ZLOAD=50Ohm at the antenna connector

2.Without neighbouring cells; without t3212 timer occurance

3.Under total mismatch conditions at antenna connector

MTX-H15 User Manual V.2.0Pag. 10 Preliminary. Subject to change without prior notice