Specification

 

 

 

 

 

ZSE30

 

 

ISE30

Rated Pressure Range

-100 to 100 kPa

 

0 to 1 MPa

Set Pressure Range

-101 to 101 kPa

 

-0.1 to 1 MPa

Withstand Pressure

500 kPa

 

 

1.5 MPa

Setting and Display Resolution

0.2 kPa

 

 

0.001 MPa

Fluids

 

Air, inert gases and

incombustible gases

Power Supply Voltage

12 to 24V DC, ±10%,ripple (p-p) 10% or less(Protected against inverse connection)

Current Consumption

 

45mA or less (No load)

Switch Output Note 1)

NPN or PNP open collector output .1 output

 

 

Max. Load Current

 

 

80mA

 

 

Max. Impressed Voltage

 

30V (During NPN output)

 

 

Residual voltage

 

1V or less (@80mA load current)

 

 

Response Time

2.5ms or less (chattering-proof function working :20,160,640 or 1280ms selectable)

 

 

Short Circuit Protection

 

 

Provided

 

Repeatability

±0.2%F.S. ±2 digits or less

 

±0.2%F.S.±1 digit or less

 

 

 

 

Voltage Output

Output Voltage : 1 to 5V ±2.5%F.S. or less (within rated pressure range)

Analog

Note 2)

Linearity : ±1%F.S. or less, Output impedance : Approx. 1k

 

Output Current : 4 to 20mA ±2.5%F.S. or less (within rated pressure range)

Output

Current Output

 

 

 

 

Note 3)

 

Linearity : ±1%F.S. or less

 

 

 

 

Max. Load Impedance : 300(@12VDC), 600(@24VDC) Min. Load Impedance : 50

 

 

 

 

 

Hyster

Hysteresis Mode

 

 

 

 

esis

Window Comparator

 

Variable(from 0)

Mode

 

 

 

 

 

 

 

 

 

 

 

 

Display

Method

3.5 digits 7-segment display, dual-color display(red/green) Sampling rate:5 times/1 sec

Indicator Accuracy

±2%F.S. ±2 digits (@25±3°C)

 

±2%F.S. ±1 digit (@25±3°C)

Indicator Lamp

 

Lit when ON (Green)

Temperature Characteristic

 

2%F.S. or less (@25 C reference)

±

 

°

Environment

 

Enclosure

 

 

IP40

 

Ambient Temperature

Operation : 0 to 50°C, Storage : -10 to 60°C (No condensation or no freezing)

 

Ambient Humidity

OperationStorage : 35 to 85%RH (No condensation)

 

 

 

 

 

 

Withstand Voltage

1000VAC,1 minute (between lead block and case)

 

 

 

Insulation Resistance

50Mor more @500VDC M (between lead block and case)

 

 

 

Vibration proof

10 to 150 Hz, 1.5mm double amplitude, 2 hours each in directions of X, Y and Z respectively

 

 

 

Impact proof

100m/s2, 3 times each in directions of X, Y and Z respectively

Standard

 

CE marking, UL/CSA(E216656)

Note 1) Analog output cannot be selected when switch output is selected.

Note 2) Both switch output and current output cannot be selected simultaneously when voltage output is selected.

Note 3) Both switch output and voltage output cannot be selected simultaneously when current output is selected.

Piping specification

 

Model

01

T1

C4H

C6H

N7H

C4L

C6L

N7L

Port size

 

R1/8

NPT1/8

 

 

M50.8

M50.8

 

 

 

 

 

 

 

One-touch fitting

 

φ4mm

φ6mm

φ1/4inch

 

straight type

 

φ5/32inch

 

One-touch fitting

 

φ4mm

φ6mm

φ1/4inch

 

elbow type

 

φ5/32inch

Material

Sensor

pressure sensing part: silicone, Pipe port: C3602 (electroless nickel plating),

O-ring: HNBR

O-ring: NBR

O-ring: NBR, Fitting: PBT

 

 

 

Lead wires with

 

81g

 

76g

 

 

78g

 

Mass

connector included (2m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Weight)

Lead wires with

 

43g

 

38g

 

 

40g

 

 

connector not included

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-8-

PS##-OMF0010-C