Sierra Products EF-3801B-AL owner manual Venting And Installation Clearances

Models: EF-3801B-AL

1 11
Download 11 pages 18.59 Kb
Page 2
Image 2
VENTING AND INSTALLATION

Figure 1 -Overall Dimensions

OU TSIDE CO MBU STION AIR IS MAND ATO RY IN MO BILE OR MO DULAR HOM E INSTALLATIONS.

CAU TIO N: D O N OT CO NN ECT T O AN Y AIR DISTRIBUTION DUCT O R SYSTEM .

VENTING AND INSTALLATION

CLEARANCES

CONT ACT LOCAL BUILDING OFFICIALS ABOUT RE- STRICTIONS AND INSTALLATION INSPECTION REQU IREM ENTS IN YOU R AREA.

A LISTED, 4" MINIMU M T YPE "L" PELLET VENT PIPE IS MANDATORY ON ALL INSTALLATIONS.

DO NO T INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOT HER APPLIANCE.

Use only listed 3" minimum Type "L" pellet vent and components for installation. The exhaust vent system must be attached to the unit and to each adjoining section. All joints for connector pipe shall be fastened with at least three screws. If vented horizontally, joints shall be made gas-tight by sealing with high temperature silicon or

m aterial spec ified by vent pipe manufacturer . Failure to use listed pellet vent pipe or install it per m anufacturers instructions will void your warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANU FACTURER

Vent Pipes’ inner and outer diameters may vary. Check with vent pipe m anufacturer for further details.

Figure 2

WARN ING : Installation of a M obile Ho me Attachment Kit P/N 10412 and outside combustion air is mandatory in mobile or modular home installations although it may

also be used in all residential applications.

An outside air inlet MU ST be provided for combustion

and ventilation air. The air inlet must remain unrestricted while unit is in use. Outside air connection is located in the rear of the heater (Figure 2). Use conduit pipe or metal flex pipe and/or fittings to mak e the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE MO BILE HOME FLOOR, WALLS AND CEILING/ROOF MUST BE MAINTAINED.

1.W hen deciding on the location of your heater and vent pipe, try to minimize the alteration and reframing of struc tural com ponents of the building . Vent pipe must be installed so that access is provided for inspection and cleaning.

2.Avoid installing heater in high traffic areas. Keep children well away from the heater when in operation.

3.A 3" clearance to combustibles must be maintained for horizontal and vertical venting. W hen passing through ceilings or walls, you must use a listed wall thimble, making sure all combustible materials and insulation products are a minimum of 3" away from the pellet vent pipe.

4.A non-com bustible hearth pad must be used if installed on a carpet, wood floor or other combusti- ble material (see Figure 3).

5.W hen installing the exhaust vent into an existing chimney, a tee must be installed behind the heater before going up into the chim ney. This is necessary in order to remove fly ash accumulation.

6.Exit termination (distance to openings):

a.3 ft. minimum above any forced air inlet located within 10 ft.

b. 4 ft. minimum below and horizontally or 1 ft. minimum above any door, window or gravity air inlet into any building.

2

Page 2
Image 2
Sierra Products EF-3801B-AL owner manual Venting And Installation Clearances