Sierra Products EF-3801B-AL owner manual Unit Installation, Autolite Installation Instructions

Models: EF-3801B-AL

1 11
Download 11 pages 18.59 Kb
Page 4
Image 4
UNIT INSTALLATION

UNIT INSTALLATION

Route the power supply cord so that it does not touch any of the exterior components of the he ater.

1.W hen exiting through the wall with your type L Pellet vent pipe, you may go straight out through a wall thim ble . You m ust connect a pellet vent tee at this point and extend the vent pipe at least 3' (three feet) vertically outside to provide good draft and allow the gases to exit. The tee must have a clean out cap for inspection and regular cleaning (Figure 4). Horizontal runs must be limited to 2' (two fe et). A w all band is required fo r every 4' (four feet) minimum on a vertical run at an exterior wall.

2.All pellet vent pipe connections including exit at the rear of the heater should be sealed with high

tem perature silicone (45 0°) or metallic duct tape. T his prevents smok e and soot leakage into the living area. If this is not done, there is a possibility that the room fan will pick up any leakage and blow it into the room.

AUTOLITE INSTALLATION INSTRUCTIONS

Th e AutoLite System is factory ins talled with the only installation requirem ents being the optional therm ostat.

Wall Thermostat Installation:

The wall therm ostat is designed to autom atically regulate the room tem perature from the control panel heat setting to the “Off” setting based upon room temperature.

Rem ember to leave the control panel on the "Medium or High" position when utilizing the wall thermostat feature.

The following is a step by step procedure for installing the optional wall therm ostat. Note connection terminals on left side of unit at rear (Figure 7,8). Use 18/2 therm ostat wire for the installation.

a.Unplug heater from wall outlet and 12VDC power!

b. Rem ove factory jump wire and hook up thermostat wires to terminals (Figure 7,8).

c.Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature.

d. Run thermostat wires from heater to thermostat along wall or under ca rpet etc. and hook wires to thermostat terminals. On new construction you can, of course, run wire in the walls before sheet rock or paneling is done.

Figure 7 Rear Connection Panel

e.Reco nnect AC power.

f.Make sure all wiring is completed before plugging the EASYFIR E Heater bac k into the wall outlet.

IMPORTANT - Any electrical work performed on the

EA SYFIRE H eater should be done by qualifie d personnel.

Figure 8 Stove Connection Panel

Remote Control Thermostat Installation:

Th e re m ote therm ostat is designed to autom atically regulate the room temperature from the control panel heat setting to the “Off” setting based upon room temp erature and place m ent of the rem ote therm ostat. Rem em ber to leave the control panel on the "Medium or High" position when utilizing the wall thermostat feature.

The following is a step by step procedure for installing the optional remote thermostat. Note connection terminals on rear of unit (Figure 1,2).

Autolite Wiring Diagram

a.Unplug heater from wall outlet and 12VDC power!

b. Mount millivolt style remote receiver box to rear of stove using double-sided tape.

b. Rem ove factory jump wire and hook up thermostat wires to terminals (Figure 7,8).

d. Reconnect AC power and follow instructions with remote thermostat regarding set up.

IMPORTANT - Any electrical work performed on the EASYFIRE H eater should be done by qualifie d personnel.

DOOR HANDLE ASSEMBLY

The door handle and latch must be assembled and adjusted prior to the operation of the stove.

1.Position handle ass em bly through door and secure with collar by sliding over shaft and tightening with allen wrench provided (Figure 9).

2.Position latch on end of shaft with flat facing allen screw. Depending on gasket, shaft will protrude approx. 1/4" through back of latch collar. Snug allen screw.

4

Page 4
Image 4
Sierra Products EF-3801B-AL Unit Installation, Autolite Installation Instructions, Wall Thermostat Installation