Raven 1x
update the MDN. Changes will automatically update the Access Overload Class values unless specifically modified using +WAOC command.
+WSID=[idx],[SID],[NID]
Set SID and NID. C3x11 and C3x11E only.
•idx=The location in the SID/NID list to store the values.
•sid=system ID
•nid=network ID
The new SID/NID values are committed to NV with the +WCMT command (AT+WCMT=1). A maximum of 20 index locations (0‐19) are supported. Error 22 is returned if the specified index value is not in the valid range.
~NAMVAL=nam[,min,msid,sid,nid]
Tip: It is recommended to use the Setup Wizard for your carrier to provision the modem.
Write account activation data. C3x10 and C3x10E only.
Following writing the values, the modem must be reset.
•nam=0
•min=phone number
•msid=second number
•sid=0 or the system ID
•nid=63355 or the network ID
Note: If ~NAMLCK has not been successfully executed, the modem returns ERROR.
•nam=0
•min=phone number
•msid=second number
•sid=0 or the system ID
•nid=63355 or the network ID
|
|
|
|
|
|
|
137 |
|
|
|
|