ATA REGISTERS

SSD-PXXX(I)-3100 DATA SHEET

SECTOR NUMBER REGISTER

The Sector Number register is set by the host to specify the starting sector number associated with the next ATA command to be executed. Following a qualified ATA command sequence, the device sets the register value to the last sector read or written as a result of the previous AT command.

When Logical Block Addressing (LBA) mode is implemented and the host issues a command, the contents of the register describe the Logical Block Number bits A[7:0]. Following an ATA command, the device loads the register with the LBA block number resulting from the last ATA command.

Table 37: Sector Number Register

Operation

D7

D6

D5

D4

D3

D2

 

D1

D0

Read/Write

 

 

Sector Number (CHS Addressing)

 

 

 

 

 

Logical Block Number bits A07-A00 (LBA Addressing)

 

 

 

 

 

 

 

 

 

 

Default Value

0

0

0

0

0

0

 

0

1

 

 

 

 

 

 

 

 

 

 

SILICONSYSTEMS PROPRIETARY

This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.

All unauthorized use and/or reproduction is prohibited.

3100P-06DSR

PAGE 50

FEBRUARY 2, 2009

Page 60
Image 60
Silicon Image SSD-P16G(I)-3100 manual Sector Number Register, Logical Block Number bits A07-A00 LBA Addressing