Simer Pumps 2110 owner manual Repair Parts / Troubleshooting

Models: 2110

1 12
Download 12 pages 19.55 Kb
Page 4
Image 4
Repair Parts / Troubleshooting

Repair Parts / Troubleshooting

4

1

2

3

4

5

5A

6

REPAIR PARTS

Key

Part Description

Qty.

2110-01

1

Handle Screw

2

670-646

2

Power Cord (8 ft.)

1

227-264-B-TSU

3

Handle

1

383-147-B

4

Motor

1

**

5

Volute Assembly

1

404-160

5A

Pump Screen

1

*

6

Volute Screw

6

670-646

*Included in Key Item 5.

**If the motor fails, replace the entire pump.

TROUBLESHOOTING

REPAIR PARTSTROUBLESHOOTINGManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Risk of electrical shock and sudden start.

Disconnect electrical power to pump before attempting to troubleshoot or work on it.

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse

If blown, replace with fuse of proper size

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring

 

 

from main switch on property. If OK, contact power company

 

Defective motor

Replace pump

 

Clogged screen

Remove volute, clean the screen and replace the volute

 

 

 

Pump operates

Low line voltage

Use only 14 gauge or larger extension cords. Use short extension cords

but delivers little

 

when necessary

or no water

Small diameter garden hose

Use larger diameter garden hose or 1” flexible pipe. Eliminate any

 

or long discharge line

excess hose. Short hoses work best

 

Check valve installed without

Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump

 

vent hole

discharge & check valve

 

Coils or bends in hose

Straighten hose

 

 

 

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Page 4
Image 4
Simer Pumps 2110 owner manual Repair Parts / Troubleshooting

FAQ

How do I troubleshoot a pump that won't start or run?

Check for blown fuses, low line voltage, defective motor, or clogged screen. Follow the corrective actions for each possible cause.

What should I do if my pump operates but delivers little or no water?

Check for low line voltage, small diameter garden hose, long discharge line, check valve installed without vent hole, or coils/bends in the hose. Take appropriate corrective actions for each issue.

How can I contact Simer Customer Service for parts or assistance?

Call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867 for help with parts or troubleshooting.