Repair Parts / Troubleshooting | 4 |
1
2
3
4
5
5A
6
REPAIR PARTS
Key | Part Description | Qty. | |
1 | Handle Screw | 2 | |
2 | Power Cord (8 ft.) | 1 | |
3 | Handle | 1 | |
4 | Motor | 1 | ** |
5 | Volute Assembly | 1 | |
5A | Pump Screen | 1 | * |
6 | Volute Screw | 6 |
*Included in Key Item 5.
**If the motor fails, replace the entire pump.
TROUBLESHOOTING
Risk of electrical shock and sudden start.
Disconnect electrical power to pump before attempting to troubleshoot or work on it.
SYMPTOM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION |
Pump won’t | Blown fuse | If blown, replace with fuse of proper size |
start or run | Low line voltage | If voltage under recommended minimum, check size of wiring |
|
| from main switch on property. If OK, contact power company |
| Defective motor | Replace pump |
| Clogged screen | Remove volute, clean the screen and replace the volute |
|
|
|
Pump operates | Low line voltage | Use only 14 gauge or larger extension cords. Use short extension cords |
but delivers little |
| when necessary |
or no water | Small diameter garden hose | Use larger diameter garden hose or 1” flexible pipe. Eliminate any |
| or long discharge line | excess hose. Short hoses work best |
| Check valve installed without | Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump |
| vent hole | discharge & check valve |
| Coils or bends in hose | Straighten hose |
|
|
|
For parts or assistance, call Simer Customer Service at