Robertson RGC12 Gyro Compass
5.5 Change Over Unit
Specifications
1. | Main power supply: | 100/220VAC 1Φ | 50/60 Hz, 16.5VA | ||
2. | Emergency power supply: | 24VDC, 13.5W | |||
3. | Output: |
| Real load repeater 1/6° 24VDC 9 circuits 8.5A max. | ||
| Digital: | 1) | Tokimec proprietary/RS422 |
| |
|
|
| (True bearing/Speed/Rate of turn) | x 4 ports | |
|
| 2) NMEA0183/RS422 (True bearing/Rate of turn) | x 8 ports | ||
| Analogue | 1) | Rate of turn | x 3 ports | |
|
|
| Scaleover Greater than ±30°/min ±5V | x 3 ports | |
|
| 2) | Rate of turn | x 3 ports | |
|
|
| Scaleover Greater than ±120°/min ±5V | x 3 ports | |
|
|
| (Analogue (2) is since SCU Ver. 1. 18. ) |
| |
| Note ! | Analogue output (1) and (2) cannot be output simultaneously. |
Repeater backup 1/6° 24VDC 3 circuits 2.5A max.
4. | Indication 7 segments: | No. 1 True bearing / No. 2 True bearing / Deviation / | ||||
|
|
|
| Deviation alarm setting / No. Alarm / No. 2 Alarm | ||
5. | Power supply specifications: |
|
| |||
|
|
| Model No. | Manufacturer | Primary (input) | Secondary (output) |
|
| PS101 | WRB24SK | ETA | 24VDC±1V | |
|
|
|
|
|
| |
|
| PS102 | ETA | +5VDC±0.3V | ||
|
|
|
|
|
| +12VDC±0.5V |
|
|
|
|
|
| |
|
| PS103 | ETA |
| +5VDC±0.3V | |
|
|
|
|
|
| +12VDC±0.5V |
|
|
|
|
|
|
6.Input : The following input signal must be applied to each
Analogue signal 200 pulse/nm dry contact | x 1 port |
Digital signal (GPS) RS422/NMEA0183 (Latitude/Longitude/Speed) | x 1 port |
38 | 20220844B |