Simrad RGC12 manual Change Over Unit, Analogue output 1 and 2 cannot be output simultaneously

Models: RGC12

1 44
Download 44 pages 50.29 Kb
Page 40
Image 40

Robertson RGC12 Gyro Compass

5.5 Change Over Unit

Specifications

1.

Main power supply:

100/220VAC 1Φ

50/60 Hz, 16.5VA

2.

Emergency power supply:

24VDC, 13.5W

3.

Output:

 

Real load repeater 1/6° 24VDC 9 circuits 8.5A max.

 

Digital:

1)

Tokimec proprietary/RS422

 

 

 

 

(True bearing/Speed/Rate of turn)

x 4 ports

 

 

2) NMEA0183/RS422 (True bearing/Rate of turn)

x 8 ports

 

Analogue

1)

Rate of turn -5 through +5V (30°/min)

x 3 ports

 

 

 

Scaleover Greater than ±30°/min ±5V

x 3 ports

 

 

2)

Rate of turn -10 through +10V (120°/min)

x 3 ports

 

 

 

Scaleover Greater than ±120°/min ±5V

x 3 ports

 

 

 

(Analogue (2) is since SCU Ver. 1. 18. )

 

 

Note !

Analogue output (1) and (2) cannot be output simultaneously.

Repeater backup 1/6° 24VDC 3 circuits 2.5A max.

4.

Indication 7 segments:

No. 1 True bearing / No. 2 True bearing / Deviation /

 

 

 

 

Deviation alarm setting / No. Alarm / No. 2 Alarm

5.

Power supply specifications:

 

 

 

 

 

Model No.

Manufacturer

Primary (input)

Secondary (output)

 

 

PS101

WRB24SK

ETA

85-264VAC 1Φ

24VDC±1V

 

 

 

 

 

47-440 Hz

 

 

 

PS102

VTM-01C-24

ETA

19-32VDC

+5VDC±0.3V

 

 

 

 

 

 

+12VDC±0.5V

 

 

 

 

 

 

-12VDC±0.5V

 

 

PS103

VTM-01C-24

ETA

19-32VDC

+5VDC±0.3V

 

 

 

 

 

 

+12VDC±0.5V

 

 

 

 

 

 

-12VDC±0.5V

6.Input : The following input signal must be applied to each gyro-compass of No. 1 and No. 2.

Analogue signal 200 pulse/nm dry contact

x 1 port

Digital signal (GPS) RS422/NMEA0183 (Latitude/Longitude/Speed)

x 1 port

38