5. Capacity table

SMF-4E27AI (7k+7k+7k+7k)

 

COOLING

 

 

 

 

 

 

 

OUTDOOR TEMPERATURE DRY

 

 

 

 

 

Indoor

 

 

 

 

21ºC

 

25ºC

 

30ºC

 

35ºC

 

40ºC

 

45ºC

 

 

Conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21ºC D

Total capacity kW

 

7.63

 

7.30

 

7.03

 

 

6.64

 

 

6.37

 

6.17

 

 

Sensitive capacity kW

 

6.11

 

5.84

 

5.63

 

 

5.31

 

 

5.10

 

4.94

 

 

15ºC W

 

 

 

 

 

 

 

 

 

Input kW.

 

 

 

1.95

 

2.23

 

2.51

 

 

2.79

 

 

3.07

 

3.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24ºC D

Total capacity kW

 

8.36

 

7.99

 

7.70

 

 

7.27

 

 

6.98

 

6.76

 

 

Sensitive capacity kW

 

6.69

 

6.40

 

6.16

 

 

5.81

 

 

5.58

 

5.41

 

 

17ºC W

 

 

 

 

 

 

 

 

 

Input kW.

 

 

 

2.06

 

2.36

 

2.65

 

 

2.95

 

 

3.24

 

3.53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27ºC D

Total capacity kW

 

9.09

 

8.69

 

8.37

 

 

7.90

 

 

7.58

 

7.35

 

 

Sensitive capacity kW

 

7.27

 

6.95

 

6.70

 

 

6.32

 

 

6.07

 

5.88

 

 

19ºC W

 

 

 

 

 

 

 

 

 

Input kW.

 

 

 

2.17

 

2.48

 

2.79

 

 

3.10

 

 

3.41

 

3.72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32ºC D

Total capacity kW

 

10.45

 

9.99

 

9.63

 

 

9.09

 

 

8.72

 

8.45

 

 

Sensitive capacity kW

 

8.36

 

7.99

 

7.70

 

 

7.27

 

 

6.98

 

6.76

 

 

23ºC W

 

 

 

 

 

 

 

 

 

Input kW.

 

 

 

2.50

 

2.85

 

3.21

 

 

3.57

 

 

3.92

 

4.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING

 

 

 

 

 

 

 

OUTDOOR CONDITIONS

 

 

 

 

 

 

Indoor

 

24ºC D

 

12ºC D

 

7ºC D

 

4ºC D

 

 

0ºC D

 

-5ºC D

-7ºC D

-15ºC D

 

Conditions

 

18ºC W

 

11ºC W

 

6ºC W

 

3ºC W

 

-1ºC W

-6ºC W

-8ºC W

-16ºC W

 

 

Capacity

14.66

 

11.73

 

9.78

 

8.80

 

 

8.31

 

 

7.33

 

6.84

6.35

 

15ºC

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input kW.

5.52

 

4.42

 

3.68

 

3.50

 

 

3.31

 

 

3.13

 

2.94

2.58

 

 

Capacity

13.77

 

11.02

 

9.18

 

8.26

 

 

7.80

 

 

6.89

 

6.43

5.97

 

18ºC

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input kW.

5.18

 

4.15

 

3.46

 

3.28

 

 

3.11

 

 

2.94

 

2.76

2.42

 

 

Capacity

12.75

 

10.20

 

8.50

 

7.65

 

 

7.23

 

 

6.38

 

5.95

5.53

 

20ºC

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input kW.

4.80

 

3.84

 

3.20

 

3.04

 

 

2.88

 

 

2.72

 

2.56

2.24

 

 

Capacity

11.73

 

9.38

 

7.82

 

7.04

 

 

6.65

 

 

5.87

 

5.47

5.08

 

22ºC

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input kW.

4.42

 

3.53

 

2.94

 

2.80

 

 

2.65

 

 

2.50

 

2.36

2.06

 

 

Capacity

10.20

 

8.16

 

6.80

 

6.12

 

 

5.78

 

 

5.10

 

4.76

4.42

 

27ºC

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input kW.

3.84

 

3.07

 

2.56

 

2.43

 

 

2.30

 

 

2.18

 

2.05

1.79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Page 11
Image 11
Sinclair SMF-C09AI, SMF-C12AI, SMF-C18AI service manual Capacity table SMF-4E27AI 7k+7k+7k+7k, Cooling, Heating