2 - AUTO MODE (GLASSFIRE)

14

BASIC FIRING STEPS

2 - AUTO MODE (GLASSFIRE)

B E G I N N E R

The GlassMaster LT controller is designed with the beginning fuser in mind. It is important to have a good general understanding of the principals of glass before programming your kiln. Therefore we recommend reading the General Firing Guidelines section of this manual before programming the kiln.

STEP 1 - START IN IDLE STATE

To start programming the kiln must be in an IdLE state. This can be verified by the display alternating between the cur- rent temperature and the message IdLE. When the kiln is first plugged in it will read “PF” indicating that there was a power

interruption. To return to IDLE Mode Press 1/8” Thick - 18” diameter or smaller

Press 1/8” Thick - 24” diameter or smaller once you are in IDLE Mode to begin the programming process.

STEP 2 - SELECT FIRING MODE

To Display Current Firing Mode Press

The display will read either “AUTO” or “PRO”. If the display reads “AUTO” it is currently set in the GlassFire Mode.

Press S 1/4” Thick - 18” diameter or smaller to select this mode..

If the display reads “PRO” it is currently set in the Ramp and Hold Mode. Press Manual background or Manual background to scroll to “AUTO”.

Press Manual background to select this mode.

STEP 2 - SELECT SPEED

The controller will display the current firing speed. The display will read SLo, MEd, or FASt for slow, medium, or fast heating rates. Use the chart to the right to help select the appropriate speed for the size of your project.

Press Manual background or Manual background to scroll to the desired firing

speed.

Press Manual background to select the displayed heating rate.

STEP 3- SELECT PROCESS

Next the controller will display the current process. The display will read SLP tAC, or FULL for slump, tac-fuse, or full-fuse pro-

cesses.

Press Manual background or Manual background to scroll to the desired

Process.

Press Manual background to select the displayed Process.

1/8” Thick - 18” diameter or smaller

FAST 1/4” Thick - 4” diameter or smaller 3/8” Thick - Not recommended

1/8” Thick - 20” diameter or smaller MEDIUM 1/4” Thick - 8” diameter or smaller 3/8” Thick - 5” diameter or smaller

1/8” Thick - 24” diameter or smaller

S 1/4” Thick - 18” diameter or smaller

LOW

3/8” Thick - 12” diameter or smaller 1/2” Thick - 8” diameter or smaller

For a metric conversion of this chart visit our website at http://www.skutt.com/glass/ products/hotstart.php