SkyLink GM-318 manual Customer Service, Installation Cont

Models: GM-318

1 2
Download 2 pages 59.77 Kb
Page 2
Image 2
4. INSTALLATION (CONT)

4. INSTALLATION (CONT)

One of

Vertical

Supports

Door closed

Door open

8. LOSS OF SIGNAL INDICATION

When the battery level on the sensor drops to a certain level, or the sensor is out of the operating range, the receiver will show a “loss of signal” indication. The red LED representing that zone will flash rapidly, i.e. if zone 1 sensor is lost, the zone 1 red LED will flash rapidly.

When the loss of signal indication occurs, move the receiver closer to the corresponding sensor and trigger that sensor. If the red LED stops flashing rapidly, that means the receiver or sensor needs to be relocated. If the “loss of signal” indication persists, replace the battery of that sensor.

Step 2 – Mount the sensor onto your garage door

You can mount the sensor onto your garage door with double-sided foam tape if the sur- face of your garage door is smooth and clean enough to provide a good adhesive surface, such surface can usually be found on a me tal garage door. Please ensure the surface is smooth and clean. Important: The bottom of the sensor should be 1/2 inch above the ground. (Refer to Diagram A)

For w ooden garage doors, it is recommended

 

to mount the sensor with screws onto the

4 Screws

garage door with 3 x 18 screws provided.

 

Double-sided foam tape

9. OTHER HOUSEHOLD ALERT ® SENSORS

The Household Alert® receiver can work with up to 4 different sensors: garage door monitor sensors, door / window sensors, water sensors, indoor/outdoor motion sensors, etc. Please visit www.skylinkhome.com or contact us at support@skylinkhome.com for more information of how to fully utilize your Garage Door MonitorTM.

Note:

When the garage door is opening/closing, make sure the sensor does not interfere with the safety reversing sensor or safety beam sensor supplied with your existing garage door opener.

Note: Ensure you straighten up the antenna

 

 

 

 

 

 

1/2 Inch

 

 

 

on the receiver to receive the best possible

 

 

 

 

 

 

 

 

 

reception.

 

 

Diagram A

5. OPERATION

When the garage door is open, the sensor will send a signal to the receiver. It will beep and the corresponding zone red LED will flash.

If the sensor is set to zone 1, zone 1 red LED on the receiver will flash, and the receiver will emit a continuous “single beep”, i.e. “beep” pause, “beep”, pause….. etc.

If the sensor is set to zone 4, zone 4 red LED will flash, and the receiver will emit a con-tinuous “4 beeps”, i.e. “beep beep beep beep” pause “beep beep beep beep” pause ……etc.

By the number of beeps emitted by the receiver, user can identify which zone is triggered.

6. BUZZER VOLUME

You can select the buzzer volume by switching the volume switch to “HI” or “LO” position.

The buzzer can be disabled by switching to the “OFF” position.

7. MUTE

When a sensor is triggered for a long period of time, you may stop the buzzer by pressing the mute button. When another signal comes again, you can disable the buzzer for all currently activated sensors by pressing

the mute button. The receive will beep again if it receives another signal.

For instance, if you are working on your lawn with the garage door open, you may want to disable the buzzer for this garage door only. Then you can press the “Mute” button after it starts to sound. If any other sensor is triggered, the receiver will sound again.

10. FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause undesired operation.

WARNING:

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter- ference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

11. WARNING

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

-Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

-ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

12. WARRANTY

If, within one year from date of purchase, this product should become defective (except battery), due to faulty workmanship or materials, it will be repaired or replaced, without charge. Proof of purchase and a Return Authorization are required.

13. CUSTOMER SERVICE

If you would like to order Skylink’s products or have difficulty getting them to work, please :

1.visit our FAQ section at www.skylinkhome.com , or

2.email us at support@skylinkhome.com , or

3.call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST. Fax (800) 286-1320

CUSTOMER SERVICE

17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Email:support@skylinkhome.com http://www.skylinkhome.com

P/N. 101A201-004 Rev.4

US Patent 6,597,291

©2005 SKYLINK GROUP

Page 2