Events and Alarms

Troubleshooting

Note Depending on the activity of your ATM SmartSwitch, the appearance of events on the ATM SmartSwitch may be too frequent to use the console comfortably. It is recommended that you turn on the automatic display of events only when troubleshooting.

Use the show alarms command to view a list of the currently logged alarms. For example,

SmartSwitch # show alarms

Index(ALL)

:

0

33554702

000:07:05:300

---------------------------------------------------

pvcm_cac_admit: failed 501037

1 33554652 023:56:23:317

---------------------------------------------------

LECS Operational

2 117506049 024:01:54:083

---------------------------------------------------

Failed to re-establish SAAL connection

Port ID 0x01c81000

T309

10000

 

3

117506049

024:01:54:430

---------------------------------------------------

More(<space>/q)?:

Alarms are displayed in the following format:

Alarm number — The index number of the alarm in the circular buffer

Alarm ID — A unique ID assigned to the alarm

Time — Time of alarm, in switch up-time in hours, minutes, seconds, and milliseconds

Object — The object affected by the alarm (port, LEC, and so on)

Alarm messages can be automatically displayed on the ATM SmartSwitch console. Use the set alarmdisplay command to display alarms on the console as they occur:

SmartSwitch # set alarmdisplay

alarmDisplay(OFF)

: on

SmartSwitch #

9.5.3Deleting Events and Alarms

To delete events or alarms currently logged within your ATM SmartSwitch, use the delete events and delete alarms commands, respectively.

9-8 SmartSwitch ATM User Guide

Page 114
Image 114
Cabletron Systems 04-0053-01 manual Deleting Events and Alarms, SmartSwitch # set alarmdisplay