Multi-level PNNI TopologyPNNI Routing

Do the same on switch SWB3:

SWB3 # set pnnipglelection

 

 

NodeIndex(1)

:

 

LeadershipPriority(0)

: 205

— Highest priority in election process

ParentNodeIndex(0)

: 2

— Node 2 will represent the peer group B in the parent group

InitTime(15)

:

 

OverrideDelay(30)

:

 

ReElectTime(15)

:

 

SWB3 #

7.Use the show pnnipglelection command to verify that switches SWA3 and SWB3 have become the PGLs of their respective peer groups. For example, on switch SWA3, enter the following:

SWA3 # show pnnipglelection

 

NodeIndex(1)

:

PGL Election Information

================================================================================

Node Index

: 1

 

Leadership Priority

: 205

 

Parent Node Index

: 2

 

Init Time

: 15 secs

 

Override Delay

: 30 secs

 

Reelect Time

: 15 secs

 

Time Stamp

: 228588

 

Election State

: Operating as PGL

— Switch SWA3 has become PGL of group A

Preferred PGL

: 50:a0:39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:20:d4:28

:c1:ff:00

 

 

Peer Group Leader

: 50:a0:39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:20:d4:28

:c1:ff:00

Active Parent Node Id : 48:50:39:00:00:00:00:00:00:00:00:00:00:00:01:00:20:d4:28 :c1:ff:00

SWA3 #

8.Physically connect switch SWA3 to SWB3 to establish connectivity between peer groups A and B.

9.Use the show pnnilink command to check the connectivity between the peer groups. In the following example, show pnnilink is entered on switch SWA3 and shows a link to switch SWB3 (SWB3’s IP address is 206.61.237.23):

SWA3

# show pnnilink

 

 

 

 

 

Num(ALL)

 

 

 

 

 

:

 

 

Num

 

Port

Node

 

Remote Node

Hello State

Link Type

 

 

 

Number

Index

 

IP Addr

 

 

 

 

===========================================================================

1

 

7A1

 

1

206.61.237.20

2WayInside

Lowest Level Horizontal Link

2

 

7A3

 

1

206.61.237.19

2WayInside

Lowest Level Horizontal Link

3

7B1

1

206.61.237.23

CommonOut

Outside and Uplink

— Physical link to switch SWB3

4

 

--

2

N/A

2WayInside

Horizontal Link to/from LGN

— Logical link between switches

SWA3

#

 

 

 

 

 

 

 

 

Note Notice that the IP address entry for the logical link between the LGNs is N/A (Not Applicable). Logical entities do not have IP addresses.

3-6 SmartSwitch ATM User Guide

Page 50
Image 50
Cabletron Systems 04-0053-01 manual Do the same on switch SWB3, SWB3 # set pnnipglelection, SWA3 # show pnnipglelection