Soft PVC and PVP Connections

Virtual Ports and Static Connections

3.Use the add spvcaddress command on the target switch to specify the target port and ATM address.

SmartSwitch # add spvcaddress

 

PortNumber()

: 6b3 — Port on target switch

AtmAddress()

: 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Added SPVC Address successfully.

 

SmartSwitch #

 

Note Both soft PVCs and Soft PVPs use the add spvcaddress command to specify the target switch’s target ATM address. There is no separate “ add spvpaddress” command.

4.Use the show spvcaddress command to see the soft PVP port and ATM address on the target switch:

SmartSwitch # show spvcaddress

 

PortNumber(ALL)

:

TargetAddress()

:

Port

SPVC Target Address

 

================================================================================

6B3

22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Total number of SPVC Addresses = 1

SmartSwitch #

5.On the source switch, use the add trafficdescriptor command to create traffic descriptors for the forward and reverse directions of the connection (See Section 5.1.1for information about traffic descriptors).

6.On the source switch, use the add spvp command to create the soft PVP connection between the two switches:

SmartSwitch # add spvp

 

 

PortNumber()

: 7a1 — Port on source switch

SourceVpi(0)

: 3

 

DestinationSelectType(REQUIRED)

:

— See note below

DestinationVPI(0)

: 3

We use VPI= 3

TargetAddress()

: 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

TransmitTrafficDescriptorIndex()

: 3

 

ReceiveTrafficDescriptorIndex()

: 3

 

RetryInterval(10000)

:

 

RetryLimit(3)

:

 

RetryThreshold(1)

:

 

SmartSwitch #

Note The DestinationSelectType determines which vpi is used on the target switch. The possible settings are REQUIRED and ANY. If DestinationSelectType is set to REQUIRED, the specified target vpi is set at the target switch. If ANY is specified, the soft PVP uses the first available vpi it finds on the target switch. If ANY is specified, enter the show spvptraget command on the target switch to determine the vpi used.

5-16 SmartSwitch ATM User Guide