Virtual Ports and Static Connections

Soft PVC and PVP Connections

1.Define a target ATM address to be used on the target switch. The target ATM address can be any address that is either eight (8) or twenty (20) bytes long and must not be identical to any address currently listed in the ATM routing table. Use the show atmroute command to check which addresses are currently defined.

SmartSwitch # show atmroute

 

Num(ALL)

:

Num Port Number ATM Address

Type Proto

================================================================================

1

--

39:00:00:00:00:00:00:00:00:00:14:41:80

I PNNI

2

--

39:00:00:00:00:00:00:00:00:00:28:8d:00

I PNNI

3

--

39:00:00:00:00:00:00:00:00:00:28:c1:80

I PNNI

4

--

39:00:00:00:00:00:00:00:00:00:29:05:00

I PNNI

5

CPU

39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:00:1d:a3:87:0b I MGMT

6

CPU

39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:00:1d:a3:87:0b I MGMT

7

CPU

39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:00:1d:a3:87:0b I MGMT

8

CPU

39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:20:d4:34:77:81 I MGMT

9

--

39:00:00:00:00:00:00:00:00:00:a3:87:0b:00:20:d4:34:77:ff I MGMT

10

--

39:00:00:00:00:00:00:00:00:00:bf:ba:26

I PNNI

11

CPU

47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT

12

--

47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I PNNI

13

CPU

c5:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT

14

--

c5:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I PNNI

SmartSwitch #

2.Use the add spvcaddress command on the target switch to specify the target port and ATM address.

SmartSwitch # add spvcaddress

 

PortNumber()

: 6b3 — Port on target switch

AtmAddress()

: 22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Added SPVC Address successfully.

 

SmartSwitch #

3.Use the show spvcaddress command to see the soft PVC port and ATM address on the target switch:

SmartSwitch # show spvcaddress

 

PortNumber(ALL)

:

TargetAddress()

:

Port

SPVC Target Address

 

================================================================================

6B3

22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22:22

Total number of SPVC Addresses = 1

SmartSwitch #

4.On the source switch, use the add trafficdescriptor command to create traffic descriptors for the forward and reverse directions of the connection (See Section 6.1.1for information about traffic descriptors).

SmartSwitch ATM User Guide 5-13

Page 79
Image 79