Bootline Commands

Firmware Upgrades and Bootline Commands

7.2.2Bootline Commands Explanations

The following table describes the commands available from the bootline prompt, their use, and their associated parameters.

Table 7-1 Bootline commands

Command

Action

Parameters

 

 

 

chpi

Change default boot load image:

chpi 0 = set boot load image 0 as default

 

Sets one of two images of the boot load

chpi 1 = set boot load image 1 as default

 

firmware as the default. Default boot load

 

 

image is executed at start-up.

 

 

 

 

clfs

Clear flash file system:

none

 

Clear flash file system of all switch

 

 

configuration information.

 

 

 

 

dcfg

Display boot load configuration:

none

 

Displays revision numbers of both boot load

 

 

images, the switch MAC address, and the file

 

 

space (in hexadecimal) available for

 

 

additional MAC addresses.

 

 

Shows whether POST is set to run at switch

 

 

start-up.

 

 

 

 

df

Download Firmware:

df B = download boot load firmware

 

Downloads firmware images from a

df S = download switch operating firmware

 

TFTP/Bootp server.

df P = download diagnostics (POST)

 

 

 

Different components of the switch firmware

df (none) = download switch operating

 

are downloaded, depending on the parameter

 

firmware

 

used with this command.

 

 

 

 

 

go

Run switch firmware:

go V = run switch firmware, do not run POST

 

Exit the bootline prompt, and run switch

go P = run POST before running switch

 

operating firmware.

firmware

 

 

go (none) = run switch firmware, do not run

 

 

POST

 

 

 

he

Show help:

he [<command>] = display help for command

 

Displays help for a bootline command or

specified

 

 

 

displays list of all bootline commands.

he = display list of all bootline commands

 

 

 

ponf

POST on or off:

ponf V = run switch firmware after start-up

 

Changes start-up action: either run POST

timeout

 

 

 

before running switch firmware or skip POST

ponf P = run POST before running switch

 

and go directly to switch firmware.

firmware

 

 

 

7-4 SmartSwitch ATM User Guide

Page 96
Image 96