SmartSwitch ATM User Guide 2-21
IP Over ATM and LANE Creating an Emulated LAN

6. On SW1, create an ELAN; in this example, we create elan1:

SW1 # add elan
ELANNumber(0) : 1
ELANName(ELAN001) : elan1
ConnectMethod(SVC) :
ELANType(802.3) :
Multipoint(YES) :
MTU(1516) :
ErrorLogEnable(NO) :
MinimumTDEnable(NO) :
Distribute(PROXY) :
SW1 #
Similarly, create the same ELAN (elan1) on SW2:
SW2 # add elan
ELANNumber(0) : 1
ELANName(ELAN001) : elan1
ConnectMethod(SVC) :
ELANType(802.3) :
Multipoint(YES) :
MTU(1516) :
ErrorLogEnable(NO) :
MinimumTDEnable(NO) :
Distribute(PROXY) :
SW2 #

7. On SW1, enter the show elan 1 command to obtain the ATM address of the LECS on that switch

SW1 # show elan 1
ELAN 1
==============================================================================
ELAN Number : 1
LECS Address : 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01 — LECS address on SW1
LES Address : 39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:03
ELAN Name : elan1
ELAN Type : 802.3
MTU : 1516
Connection Method : SVC
Distribute VPI/VCI: 0/0
Distribute Method : PROXY
Multipoint : YES
Error Logging : NO
Min TD Negotiation : NO
SW1 #