Locally Attached returns yes. If the server is

IP Over ATM and LANE

Creating an Emulated LAN

To see a list of servers (LES/BUS or SMS servers) known to a particular LNNI LECS, enter the show lecsserverlist command on a switch running an LNNI LECS:

SW1 # show lecsserverlist

 

ELANNumber(ALL)

: 1

LES/SMS servers known for ELAN 1

==============================================================================

ATM Address

:

39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:03

Learned From (LECS):

39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01

Type

:

LES

 

Alive Time (secs)

:

28

 

Locally Attached

:

Yes

 

Config Direct VCC

:

0/47

 

Server ID

:

0x0000

 

LECID Range

:

0x0001 - 0x03FF

ATM Address

:

39:00:00:00:00:00:00:00:00:00:BD:AE:20:00:00:1D:BD:AE:20:03

Learned From (LECS):

39:00:00:00:00:00:00:00:00:00:A3:87:0B:00:00:1D:A3:87:0B:01

Type

:

LES

 

Alive Time (secs)

:

27

 

Locally Attached

:

Yes

 

Config Direct VCC

:

0/59

 

Server ID

:

0x0001

 

LECID Range

:

0x0400 - 0x07FF

ATM Address

:

39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:03

Learned From (LECS):

39:00:00:00:00:00:00:00:00:00:BF:BA:26:00:00:1D:BF:BA:26:01

Type

:

LES

 

Alive Time (secs)

:

21

 

Locally Attached

:

No

— LES/BUS of this switch (SW3) is not associated with switch SW1

Config Direct VCC

:

--

 

Server ID

:

--

 

LECID Range

:

--

 

SW1 #

In this example, show lecsserverlist is entered on SW1. Notice that the parameter Locally Attached indicates whether the server is associated with the LECS on the switch on which the show lecsserverlist command was executed. If the server is associated with this switch’s LECS (SW1),

associated with an LECS on a different switch, Locally Attached returns no.