Route Metrics

Routing

1.Create the outgoing member of the metric pair:

SmartSwitch # add pnnimetric

 

 

Executing this command : add PnniMetrics

 

 

MetricsTag(1)

: 9

 

TrafficDirection(Outgoing)

:

— 1st pair member, we accept the default (Outgoing)

ServiceCategory(UBR)

: cbr

 

GCAC_CLP(2)

:

 

AdminWt(5040)

: 200

 

MaxCellRate(NotUsed)

: 1000

AvailableCellRate(NotUsed)

: 750

 

MaximumCellTransferDelay(NotUsed)

:

 

CellDelayVariation(NotUsed)

:

 

CellLossRatioForCLP=0(NotUsed)

:

 

CellLossRatioForCLP=0+1(NotUsed)

:

 

CellRateMargin(NotUsed)

:

 

VarianceFactor(NotUsed)

:

 

SmartSwitch #

2.Create the incoming member of the metric pair:

SmartSwitch # add pnnimetric

 

Executing this command : add PnniMetrics

 

MetricsTag(1)

: 9

TrafficDirection(Outgoing)

: incoming — 2nd pair member, we set as incoming

ServiceCategory(UBR)

: cbr

GCAC_CLP(2)

:

AdminWt(5040)

: 200

MaxCellRate(NotUsed)

: 1000

AvailableCellRate(NotUsed)

: 750

MaximumCellTransferDelay(NotUsed)

:

CellDelayVariation(NotUsed)

:

CellLossRatioForCLP=0(NotUsed)

:

CellLossRatioForCLP=0+1(NotUsed)

:

CellRateMargin(NotUsed)

:

VarianceFactor(NotUsed)

:

SmartSwitch #

3.Enter show pnnimetric to view the newly created metric pair:

SmartSwitch # show pnnimetrics

 

 

 

 

Metrics(ALL)

 

 

:

 

 

Metrics

Metrics Tag

Direction

Index

GCAC CLP

Admin Wt Service Categories

================================================================================

1

0x9

Incoming

0x10

CLP0+1

200

CBR — Incoming pair member

2

0x9

Outgoing

0x10

CLP0+1

200

CBR — Outgoing pair member

3

0x111113

Outgoing

0x1

CLP0+1

5040

UBR

4

0x111113

Outgoing

0x2

CLP0+1

5040

ABR

5

0x111113

Outgoing

0x4

CLP0

5040

NRTVBR

6

0x111113

Outgoing

0x18

CLP0

5040

CBR RTVBR

7

0x111114

Outgoing

0x1

CLP0+1

5040

UBR

8

0x111114

Outgoing

0x2

CLP0+1

5040

ABR

9

0x111114

Outgoing

0x4

CLP0

5040

NRTVBR

10

0x111114

Outgoing

0x18

CLP0

5040

CBR RTVBR

SmartSwitch #

The newly created metric pair appears at the top of the list as metrics 1 and 2.

4-8 SmartSwitch ATM User Guide

Page 64
Image 64
Cabletron Systems 04-0053-01 Create the outgoing member of the metric pair, Create the incoming member of the metric pair