Door/Window Alert | Model |
1. INTRODUCTION
2. SET UP CODE CONNECTORS AND ZONE CONNECTORS
The Door/Window Alert is designed to monitor any door or window within your house. When the monitored window or door is opened, the receiver will alert you. It will beep and flash.
In this package, you should find a sensor, a magnet, a Houselink® receiver, an adapter, 3V lithium battery, a clip and other mounting accessories.
| Magnet | Sensor |
|
| |
| Clip |
|
Adapter | 3V Lithium |
|
|
| |
| battery |
|
| 2 pcs 3.5 x 18 screws | Houselink® |
Mounting | 2 pcs 3.5 x 12 screws | |
plate |
| Receiver |
1. CODE CONNECTORS
In order for the sensor to communicate with the receiver properly, the sensor’s code must match with the receiver’s code. Code connectors 1 to 6 can be found by opening the top cover of the sensor and the back cover of the receiver. User is required to set these code connectors randomly and the code settings on the sensor and receiver must be the same. Each position of the code connector can be set to “+”,
Clip
‘0’
‘+’
Note: If you experience interference from a nearby system, which could accidentally trigger your system, please change the code settings on the sensor and receiver. The code setting on the sensor and receiver should still match after changing the code setting.
2. ZONE CONNECTORS
Each receiver can work with up to 4 different sensors (to represent 4 different zones on the receiver). There are 2 connectors that deter- mine the zone number 1, 2, 3 and 4. These 2 connectors can be found by opening the top plastic cover, near the code connectors with marking “A” & “B”. Please follow Table 1 to set the zone.
|
|
| A | B |
|
|
|
|
|
| Zone 1 |
| + | + |
| Zone 2 |
| + | - |
Zone | Zone 3 |
| - | + |
connectors | Zone 4 |
| - | - |
|
| |||
|
| Table 1 |
|
“+” in the table means the connector for that position should be placed on the posts.
Please follow the instructions below to set up the door / window sensor and the receiver.
Open the top cover | Code Connectors on Sensor | Code Connectors on Receiver |
3. POWER UP THE DOOR/WINDOW SENSOR AND RECEIVER
4. INSTALLATION
After setting up all the connectors, both units are ready to be powered up.
Plug in the adapter to the receiver, the green LED will start flashing indicating the receiver unit is powered up but no sensor is detected. Remove the top cover of the sensor and insert the 3V lithium battery to the sensor as shown in the diagram.
“+” positive side up
Before inserting the battery, keep the magnet away from the sensor. After inserting the battery to the door / window sensor, the receiver will beep and flash. If the door / window sensor is set to zone 1, zone 1 red LED will flash. The beeping and flashing will continue until the magnetic contact is close to the sensor.
You are now ready to install the sensor and the magnet to a door or window.
Note: The receiver may not be able to receive the signal from the sensor properly if they are too close to each other. Move the sensor further from the receiver to test again.
When the magnetic contact is closed, the receiver will not beep.
SELECT A MOUNTING LOCATION
The sensor should be mounted on the door / window frame and the magnet should be mounted on the door / window itself. Mount the sensor or magnet as high as possible.
You should find a grey alignment marking on one side of the sensor. The magnet should be in contact with this marking when the door / window is closed (Refer to Diagram A).
|
| When the magnetic contact is |
|
| broken (open), the receiver will |
Plug in the adapter to the receiver | Insert 3V lithium battery to the sensor | beep and a LED will flash. |