Command Command target range Response
set red [value] =0 to =100 red=[value]
set green [value] =0 to =100 green=[value]
set blue [value] =0 to =100 blue=[value]
set cyan [value] =0 to =100 cyan=[value]
set magenta [value] =0 to =100 magenta=[value]
set yellow [value] =0 to =100 yellow=[value]
set videofreeze [target] =on
=off
videofreeze=[target]
set cc [target] =cc1
=cc2
=off
cc=[target]
N O T E
Typically, cc1 displays English (U.S.) subtitles, while cc2 displays other regional languages, such
as French or Spanish, depending on television channel or media setup.

Additional VGA source controls

Your VGA source supports all the general source controls described in General source controls on
the previous page, as well as the commands listed in this section. These settings are unavailable
when the projector is in Standby mode or when the VGA sources are disconnected.
N O T E
Some of these commands are invalid with HDMI input and Composite video sources, and will
return the response “invalidcmd=[command]”.
These commands inform you of the current VGA source settings.
Command Response
get frequency frequency=[current frequency offset setting]
get tracking tracking=[current tracking offset setting]
get saturation saturation=[current saturation setting]
get tint tint=[current tint setting]
get sharpness sharpness=[current sharpness setting]
A P P E N D I X B
Remotely managing your system through an RS-232 serial interface
84