Smeg ADP8252 manual Not Working Properly?, Check These Points First, Alarm E1, Alarm E2, Alarm E3

Models: ADP8252

1 20
Download 20 pages 21.57 Kb
Page 17
Image 17
Not Working Properly?

Not Working Properly?

15

Check These Points First

The electronic control system is capable of detecting 6 possible dishwasher malfunctions. Therefore before calling the After-Sales Service, users are advised to consult the list below, and in all cases to make a note of the error messages.

Alarm E1

NOT USED ON THIS APPLIANCE.

Alarm E2

The system which limits the water level inside the dishwasher (Safety Level) has been tripped. Since this might be a temporary fault, try reprogramming the machine. If the malfunction persists, call the After-Sales Service.

Alarm E3

The dishwasher is not able to heat the washing water correctly. To establish the cause of the fault call the After-Sales Service.

Alarm E4

The temperature monitoring system has failed. Switch off the dishwasher, switch it back on and restart a washing programme. If the alarm appears again, call the After-Sales Service, specifying the number of the error.

Alarm E5

The dishwasher is not able to take in water. Check that:

A)the water cock is open;

B)the filter in the pipe is not blocked;

C)there are no restrictions in the filter pipe.

After making these checks, close the door. The washing programme will restart from the point where it was interrupted. If the alarm persists call the After-Sales Service.

Alarm E6

The dishwasher is unable to discharge the water. Check that:

A)the drain hose is not crushed;

B)the drain line is not blocked.

After making these checks, close the door. The washing programme will restart from the point where it was interrupted. If the alarm persists call the After-Sales Service.

Page 17
Image 17
Smeg ADP8252 Not Working Properly?, Check These Points First, Alarm E1, Alarm E2, Alarm E3, Alarm E4, Alarm E5, Alarm E6