Instructions for the Installer
ADJUSTING THE BURNER MINIMUM SETTING
CONVERTING FROM LPG TO NATURAL GAS
Perform the operations described below on all the gas taps.
1Pull off the knob.
2Make sure that the
3Turn the bypass as stated in the BURNER
CHARACTERISTICS, NOZZLES AND GAS CONSUMPTION table (see page 10).
4When adjustments are complete, fit the knob, light the relative burner and turn it to the minimum setting . The flame should be even at the minimum setting.
5Check that the flame remains stable when the knob is turned quickly from the maximum to the minimum setting. The flame must not go out.
6If the minimum flame is not even, remove the knob and make small clockwise or
CONVERTING FROM NATURAL GAS TO LPG.
Perform the operations described below on all the gas taps.
1Pull off the knob.
2Turn the
3For the grill tap, after screwing the bypass fully down back it off by 1+1/4 turn.
14