Instructions for the Installer
ADJUSTING THE PRIMARY AIR FLOWS
The operations below must be carried out for every burner in the barbecue section:
ADJUSTING THE PRIMARY AIR FLOW FOR "U"- SHAPED BURNERS
1 Undo the adjuster screw A of the air regulator
A
sleeve.X
2Turn the regulator sleeve B into the position for the type of gas to be used, consulting the table below.
3Tighten the regulator screw, making sure that the distance X is correct (see table below).
ADJUSTING THE PRIMARY AIR FLOW FOR "PARALLEL FLAME" BURNERS
1Undo the adjuster screw A of the air regulator sleeve.
2Pull the regulator sleeve B out or push it in to achieve the position for the type of gas to be used, consulting the table below.
3Tighten the regulator screw, making sure that the X
distance X is correct (see table below).
A
B
B
NATURAL GAS
(N)
G30/G31 (LPG) | NATURAL GAS (N) |
| Parallel flame |
burners | burners |
G30/G31 (LPG) Parallel flame burners
X =
4 mm
8 mm
2 mm
8 mm
13