Instructions for the installer

4.2 Burner and nozzle characteristics table (60 cm model);

 

Rated heating

 

 

 

 

 

 

Burner

capacity (kW)

 

LIQUID GAS – G30/G31 28/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

By-pass

Reduced

Capacity

Capacity

 

 

 

diameter 1/

1/100

capacity

g/h G30

g/h G31

 

 

 

100 mm

mm

(W)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

50

30

400

73

71

 

Semi rapid

1.8

65

33

500

127

125

 

Ultra-rapid

4.0

100

65

1600

290

286

 

Oven

3.2

87

50

900

233

229

 

 

Rated heating

 

 

 

 

 

 

Burner

capacity (kW)

 

LIQUID GAS – G30/G31 28/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated heating

 

 

 

 

 

 

Burner

capacity

 

TOWN GAS – G110 8 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

Reduced

 

 

 

 

 

diameter

 

capacity

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

 

145 (/8)

 

400

 

 

Semi rapid

1.8

 

185 (/2)

 

500

 

 

Triple crown

4.0

 

350 (/13)

 

1200

 

 

Oven

3.2

 

270

 

900

 

 

The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.

 

Rated heating

 

 

Burner

capacity

NATURAL GAS – G20/G25 20/25 mbar

 

(kW)

 

 

 

 

 

 

 

 

Nozzle

Reduced

 

 

diameter

capacity

 

 

1/100 mm

(W)

 

 

 

 

Auxiliary

1.0

72 (X)

400

Semi rapid

1.8

97 (Z)

500

Ultra-rapid

4.0

135 (K)

1600

Oven

3.2

130

900

 

 

 

 

81

Page 10
Image 10
Smeg C6GVXI Burner and nozzle characteristics cm model, Capacity G30 G31 100 mm, Burner Capacity Town GAS G110 8 mbar