Instructions for the installer

4.3 Burner and nozzle characteristics table (90 cm model);

 

Rated heating

 

 

 

 

 

 

Burner

capacity (kW)

 

LIQUID GAS – G30/G31 28/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

By-pass

Reduced

Capacity

Capacity

 

 

 

diameter 1/

1/100

capacity

g/h G30

g/h G31

 

 

 

100 mm

mm

(W)

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

50

30

400

73

71

 

Semi rapid

1.8

65

33

500

127

125

 

Rapid

3.0

85

45

800

218

214

 

Ultra-rapid

4.0

100

65

1600

291

286

 

Maxi oven

5.2

110

59

1300

378

371

 

 

 

 

 

 

 

 

 

 

Rated heating

 

 

 

 

 

 

Burner

capacity

 

TOWN GAS – G110 8 mbar

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle

 

Reduced

 

 

 

 

 

diameter

 

capacity

 

 

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

 

 

 

 

Auxiliary

1.0

 

145 (/8)

 

400

 

 

Semi rapid

1.8

 

185 (/2)

 

500

 

 

Rapid

3.0

 

260 (/3)

 

800

 

 

Triple crown

4.0

 

350 (/13)

 

1200

 

 

The nozzles and data concerning TOWN GAS are available at the Authorised Service Centres.

 

Rated heating

 

 

Burner

capacity

NATURAL GAS – G20/G25 20/25 mbar

 

(kW)

 

 

 

 

 

 

 

 

Nozzle

Reduced

 

 

diameter

capacity

 

 

1/100 mm

(W)

 

 

 

 

Auxiliary

1.0

72

400

Semi rapid

1.8

97

500

Rapid

3.0

115

800

Ultra-rapid

4.0

135

1500

Maxi oven

5.2

164

1300

 

 

 

 

82

Page 11
Image 11
Smeg C6GVXI manual Instructions for the installer