Smeg CIR60XS manual Instructions for the installer

Models: CIR60XS CIR60X

1 24
Download 24 pages 46.19 Kb
Page 7
Image 7
be protected in accordance with Clause 5.12.1.2 to a height C of not

Instructions for the installer

be protected in accordance with Clause 5.12.1.2 to a height C of not

less than 150 mm above the hob for the full dimension (width or depth) of the cooking surface area. Where the cooking appliance is

fitted with a ‘splashback’, protection of the rear wall is not required.

3Additional requirements for Freestanding and Elevated Cooking

Appliaces – (Measurements D & E)

Where D, the distance from the periphery of the nearest burner to a horizontal combustible surface is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the trivet. See insets above.

NOTES

1Requirement 3 does not apply to a freestanding or elevated cooking appliance which is designed to prevent flames or the cooking vessels from extending beyond the periphery of the appliance.

2The ‘cooking surface area’ is defined as that part of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs.

3For definition of hob, see Clause 1.4.64.

4For definition of trivet, see Clause 1.4.109.

5Consideration is to be given to window treatments when located near cooking appliances. See Clause 5.3.4.

9

Page 7
Image 7
Smeg CIR60XS manual Instructions for the installer, be protected in accordance with Clause 5.12.1.2 to a height C of not