Instructions for the installer

The connection to the mains shall be done conforming to the regulations in force. Check that the power line is adequately grounded. Do not use reducers, adapters or shunts. On the power line, install an omnipolar cut- off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

The connection terminals are located at the rear of the

appliance. For electrical connections see following diagram. To access, remove the rear cover.

For operation on 380-415V3N: use an H05RR-F-typefive-core cable (5 x 1.5 mm2).

For operation on 380-415V2N: use an H05RR-F-typefour-core cable (4 x 2.5 mm2).

For operation on 220-240V: use an H05RR-F-typethree-core cable (3 x 4 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.

45

Page 5
Image 5
Smeg CS120A-6, CS120-6 manual Instructions for the installer