Installer Instructions
2.4.2Butane/propane gas connection
For butane, use a pressure regulator on the gas cylinder in accordance with the regulations in force and a flexible hose in accordance with Standard
2.4.3Connection using a collapsible steel tube
The gas can be connected using a flexible rubber hose (Standards
The connection point on the appliance is a threaded ½” male gas connection.
2.4.4Natural gas connection
The gas can be connected using a flexible rubber hose (Standards
Flexible hose/collapsible tube L must be connected directly to the end of pipe B of the appliance, interposing seal C between the two. The connection point on the appliance is a threaded ½” male gas connection.
2.4.5Butane/propane gas connection
Use a pressure regulator in accordance with the regulations in force and carry out the connection to the cylinder in accordance with the regulations in force. Make sure that the feed pressure is in accordance with the values specified in the table in paragraph "3.2/3.3 Tables for burner and injector characteristics"
Screw hose guide F onto hose guide A; connect the resulting assembly to gas fitting B (or use hose guide G which must be connected directly to gas fitting B) and interpose seal C in between the two. Mount the ends of rubber hose H onto hose guides A+F (or G if appropriate) and the outlet fitting of the pressure regulator onto the cylinder. Fix the ends of hose H onto hose guides A+F (or G if appropriate) using bearing I in accordance with the regulations in force.
8