Smeg CS15-5 manual Adaptation To Different Gas Types, 3.1Replacing the hob injectors

Models: CS15-5

1 20
Download 20 pages 17.61 Kb
Page 7
Image 7
3 ADAPTATION TO DIFFERENT GAS TYPES

Installer Instructions

2.4.6Connection using a collapsible steel pipe (for all gas types)

This connection type can be used for both of the installation methods shown in figures "A" and "B" in chapter “2. INSTALLING THE APPLIANCE”. Only use collapsible steel pipes that meet the requirements of the regulations in force with a maximum length of 2 metres.

Screw the end of collapsible pipe L onto external threaded ½” gas fitting B (ISO 228-1), interposing seal C in between the two.

Once the installation is completed, check for any leaks using a soapy water solution, never using flame.

3 ADAPTATION TO DIFFERENT GAS TYPES

Before carrying out any procedure, cut the electrical supply to the appliance.

The cooking range hob is set to use natural gas G20/G25 (2E+) at a pressure of 20/25 mbars in cooking ranges with a large oven, and butane/propane gas G30/G31 (3+) at a pressure of 28/37 mbars in cooking ranges provided with a cylinder housing. Moreover, the guide eye of the hose must be replaced with the appropriate one provided. If other types of gas are used, the burner injectors must be replaced, then the minimum flame must be adjusted on the gas taps. To replace the injectors, follow the instructions set out below.

3.1Replacing the hob injectors

This process does not require the primary air supply to be adjusted.

1.Remove the racks, take out all flame spreaders and caps;

2.use a 7-mm tubular spanner to unscrew the burner injectors;

3.replace the burner injectors according to the gas to be used and as described in paragraph “3.2/3.3 Tables of burner and injector characteristics”.

4.Put the burners back into their housings correctly.

9