Instructions for the installer

2. POSITIONING OF HOB

The following operation requires building and/or carpentry work so must be carried out by a competent tradesman.

Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C).

2.1.1Attachment to support structure Create an opening with the dimensions shown in the figure in the top surface of the counter, keeping a minimum distance of 50 mm from the rear border.

This appliance can therefore be mounted against walls higher than the work surface on condition that a certain distance “X” be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating.

Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them.

Carefully position the insulation gasket (supplied) on the external perimeter of the hole made in the top surface (see figures below) and try to make it stick to the entire surface by applying light pressure with your hands. Refer to the coordinates shown in the figure, bearing in mind that sides A should be adjacent to the hole. Secure the hob to the counter with brackets B (supplied). Carefully trim any excess from border C of the gasket. The distances in the following drawing refer to the hole on the inner side of the gasket.

21

Page 4
Image 4
Smeg ER12550NL, ER12150EU, ER12550EU, ER12150PP, ER12150NL manual Instructions for the installer, Positioning of HOB