2.2.1 Ovens with top controls

Instructions for the installer

2.2.1 Ovens with top controls

In the ovens with top controls the power cable is not supplied. Use a H05RR-F or H05RN-F rubber-sheathed cable making sure that it does not come into contact with any external metal parts of the oven when routing. Remove rear cover by loosening relevant screws to gain access to the terminal strip. If necessary change jumper configuration as shown in the figure and then connect wires making sure that the earth wire is at least 20 mm longer than the others. Secure power cable to oven by means of the appropriate fitting.

.

For operation on 230V: use an H05RR-F

/H05RN-F type three-core cable (3 x 2.5 mm2).

For operation on 400V2N: use an H05RR-F /H05RN-F type four-core cable (4 x 2.5 mm2).

For operation on 400V3N: use an H05RRF / H05RN-F type five-core cable (5 x 1.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.