Instructions for the installer
Burner |
|
|
| Rated |
| Town gas G110 – 0.8 kPa | |||
|
|
| heating |
| |||||
|
|
|
|
| capacity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Nozzle diameter | Reduced flowrate | |
|
|
|
|
|
|
| 1/100 mm |
| (W) |
|
|
|
|
|
|
|
|
|
|
Auxiliary |
| 1.05 | 132 | 380 | |||||
|
|
|
|
|
|
|
|
|
|
Semirapid |
| 1.65 | 165 | 380 | |||||
|
|
|
|
|
|
|
|
|
|
Rapid |
| 2.55 | 210 | 600 | |||||
|
|
|
|
|
|
|
|
| |
Rapid large | 3.1 | 240 | 800 | ||||||
|
|
|
|
|
|
|
|
|
|
Fish pan |
| 1.8 | 177 | 750 | |||||
|
|
|
|
|
|
|
|
|
|
Ultra rapid |
| 3.3 | 250 | 900 | |||||
|
|
|
|
|
|
|
|
|
|
Double |
| Internal |
|
| 0.8 |
| 115 |
| 380 |
crown |
|
|
|
|
|
|
|
|
|
| External |
| 3.3 | 250 | 900 | ||||
|
|
|
|
|
|
|
|
|
|
Regulation of primary air
Referred to distance “X” in mm.
Burner |
|
|
| G20 | |
|
|
| 2.0 kPa | ||
|
|
|
|
| |
|
|
|
|
|
|
Auxiliary (1) |
| 1.5 | |||
|
|
|
|
|
|
Semirapid (2) |
| 1.5 | |||
|
|
|
|
|
|
Rapid (3) |
| 1.0 | |||
|
|
|
|
|
|
Rapid large (4) | 1.5 | ||||
|
|
|
|
|
|
Fish pan (7) |
| 2.5 | |||
|
|
|
|
|
|
Ultra rapid (5) |
|
| 1.5 | ||
|
|
|
|
|
|
Double |
| Internal |
|
| 1.5 |
crown (6) |
|
|
|
|
|
| External |
| 1.5 | ||
|
|
|
|
|
|
G30/G31 |
| G110 |
2.8 kPa |
| 0.8 kPa |
1.00.5
1.50.5
1.51.0
2.51.0
2.01.0
2.51.0
1.50.5
4.01.0
13