5.2Regulation for LPG

Instructions for the installer

5.2Regulation for LPG

Loosen screw C and push air regulator D to the bottom.

With a 7 mm wrench, remove nozzle E and replace it with the proper one (follow the instructions on the reference tables for the type of gas to be used). The torque wrench setting of the nozzle must not exceed 3 Nm.

Regulate the air by sliding regulator D until reaching distance “X” shown in the table in paragraph “5.4 Regulation of primary air ”.

Lock regulator D by tightening screw C.

Rated

BurnerheatingLPG – G30/G31 28/37 mbar capacity

(kW)

Nozzle

 

By-pass

 

Reduced

 

Flowrate

 

Flowrate

diameter

 

mm

 

flowrate

 

g/h G30

 

g/h G31

1/100 mm

 

1/100

 

(W)

 

 

 

 

Auxiliary

 

Semi rapid

 

Medium rapid

 

Large rapid

 

UR

A

B

 

1.0

1.6

2.3

3.0

3.6

48

62

75

82

76

48

30(**)

30 (*)

30(**)

33 (*)

40(**)

40 (*)

40(**)

45 (*)

48 (**)

50 (*)

450 73 72

500 116 114

700

167

164

800

218

215

1000 261 257

*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown inpoint “5.6 Regulation of minimum for natural gas”.

CAUTION: for references A and B on the lh UR and rh UR burners, see drawings at side.

5.3Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG ”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “5.4 Regulation of primary air ”.

Burner

Auxiliary

 

Semi rapid

 

Medium rapid

 

Large rapid

 

UR

A

B

 

 

Rated

 

 

 

 

 

 

heating

 

Natural gas – G20 20 mbar

 

 

capacity

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nozzle diameter

 

Reduced flowrate

 

 

 

1/100 mm

 

(W)

 

 

 

 

 

 

1.0

 

73

 

400

 

 

 

 

 

 

 

1.65

 

92

 

500

 

 

 

 

 

 

 

2.3

 

110

 

700

 

 

 

 

 

 

 

3.0

 

126

 

800

 

 

 

 

 

 

 

 

3.6

 

115

 

1000

 

 

 

 

 

 

 

 

 

73

 

 

 

26

Page 9
Image 9