Instructions for the installer
5 FINAL OPERATIONS
After carrying out the above adjustments, remount in reverse order to the instructions given in paragraph “3.1 Replacement of nozzles on the hob”.
After having regulated the device with gas other than the one tested, replace the label located on the guard with the one that corresponds to the new gas.
The label is available from your nearest Authorised Assistance Centre.
5.1Regulation of minimum for town gas and natural gas
Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame.
Replace the knob and check burner flame stability: (when you turn the knob quickly from maximum to minimum position, the flame should not go out). Repeat this operation for all the gas taps.
5.2Lubrication of gas taps
With time it may happen that the gas taps get blocked and hard to turn. Clean them inside and
by an authorised person.
16