Instructions for the installer

3.2Burner and nozzle characteristics table

Burner

Auxiliary (1)

Semi rapid (2)

Rapid (3)

Ultra rapid (4)

Rated

heating

capacity

(kW)

1.05

1.75

2.3

3.5

LPG – G30/G31 30/37 mbar

Nozzle

 

By-pass

 

Reduced

 

Flow rate

 

Flow rate

diameter

 

 

mm

 

flow rate

 

g/h G30

 

g/h G31

1/100 mm

 

1/100

 

(W)

 

 

 

 

 

 

 

 

 

 

 

 

50

 

30(*)

 

 

28 (**)

 

350

 

76

 

75

 

 

 

 

 

 

65

 

33(*)

 

 

32 (**)

 

450

 

130

 

128

 

 

 

 

 

 

75

 

45(*)

 

 

42 (**)

 

800

 

166

 

164

 

 

 

 

 

 

94

 

65(*)

 

 

63 (**)

 

1.6

 

253

 

250

*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown in point “4.1 Regulation of minimum for natural gas”.

Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Auxiliary (1)

Semi rapid (2)

Rapid (3)

Ultra rapid (4)

1.05

1.75

2.3

3.5

Rated

Nozzle diameter

1/100 mm

72

97

103

133

Reduced flow rate

(W)

350

450

800

1500

Burner

heating

capacity

(kW)

Town gas – G110 8 mbar

Auxiliary (1)

Semi rapid (2)

Rapid (3)

Ultra rapid (4)

1.05

1.75

2.3

3.3

Nozzle diameter

1/100 mm

145

185

220

290

Reduced flow rate

(W)

350

450

800

1500

Values for town gas are based on category III 1a2H3+ appliances.

3.3Arrangement of burners on cooking hob

BURNERS

1 Auxiliary

2 Semi rapid

3 Rapid

4 Ultra rapid

31

Page 12
Image 12
Smeg PGF95BE-2, PGF95-2 manual Burner and nozzle characteristics table, Arrangement of burners on cooking hob