6)

7)

8)

9

10)

Leak testing of the appliance must be conducted according to the following instructions:

Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections indicate a leak. If a leak appears, shut off gas valve controls and adjust connections.

Then check the connections again.

NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES.

Remove all of the detergent solution from the cooktop.

Electronic Ignition System - initial lighting

Cooktop burners use electronic igniters rather than standing pilots. When the cooktop control

knob is pushed in and turned to the "NATURAL GAS:" position, the system lights a spark to ignite the burner. This sparking continues until the control knob is turned to the desired setting.

Check the operation of the cooktop burners. Push in and turn each control knob to the maximum flame

position (Manual background). The flame should light within 4 seconds.

If the burners do not light properly, turn the control knob to the O position. Ensure that the burner cap is in the proper position. Ensure that the power supply cord is plugged in and that the circuit breaker or house fuse has not blown. Ensure that the shut-off valve is on the "ON" position. Check operation again. If a burner does not light at this point, contact your SMEG dealer for assistance.

Replace the components on the burner and turn the knobs on the gas tap pins.

Light the burner and set it at minumum Manual background.

Remove the knob and turn the regulation screw next to the gas tap pin until you obtain a suitable minimum flame.

Replace the knob and check flame stability by rapidly turning the knob from maximum to minimum. The flame should not go out.

Check flame at the maximum flame position (Manual background) for a blue color. It should be clean and soft in character. No blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect different elements in the air or gas.

Completely fill out conversion label (part no. XXXXXXX) and attach the label to the bottom of the cooktop beside the rating tag. Do not cover the rating tag with the conversion label.

11)

At higher altitudes, no further adjustments are necessary. Derating the burners is also unnecessary.

 

 

12)

Save the orifices removed from the unit along with these instructions for possible future use.

 

NATURAL GAS:

 

To convert back to Natural Gas: Follow steps 3 through 11 and replace orifices in the order in which they

 