TRANSFORMATIONS
Before any kind of transformation is necessary to cut off the electricity.
6)TRANSFORMATION OF THE INPUT TYPE
The standard equipment of the appliances is for single phase connection. In any case, under proper changes, they can be fed with a three phase system.
To obtain these changes, please, follow the instructions:
a)Take off the panel stuck by screws "V" (see fig. 14).
b)Remove the connection jumpers on the clamp following the scheme of fig.15 of page (attached on the body).
c)Insert the input cable with adequate section (see scheme paragraph 5) into the chock.
d)Connect the phase cable into the clamp and the "earth" cable in the relative clamp.
e)Hold up the input cable with the pertinent stopcable.
f)Replace the panel in its seat and hold up with the pertinent screws "V" (see fig. 14).
FIG. 14
FIG. 15
26