Smeg SBC30 manual Electrical Connection, Installation

Models: SBC30

1 15
Download 15 pages 10.21 Kb
Page 9
Image 9
5) ELECTRICAL CONNECTION

INSTALLATION

5) ELECTRICAL CONNECTION

The electrical connection has to be done in accordance with all electrical and installation requirements of the regulation.

Before proceeding with the connection, please, verify that:

-The power of the electrical system and the power of the outlets is adequate to the maximum power of the appliance (see the identification label in the lower part of the body).

-The outelets and all the electrical system has an efficient connection to the "earth" according with the Regulation. We disclaim all responsabilities for not observing such points.

-If the appliance is not equipped with an input cable, connect to the clump with an adequate section cable (see scheme paragraph 6) keeping the "earth" conductor longer than "live" ones,

following the scheme of fig. 12 and 13.

When the connection to the input system has been done through a outlet:

-Apply to the input cable "C", if unprovided, a normalized plug adequate to the load indicated in the identification label. Connect the cables according to the scheme of fig.12 and fig. 13, making sure to respect the undermentioned respondences:

Letter L (Live) = cable brown colour; Letter N (Neutral) = cable blue colour; Symbol ￿￿ (Earth) = cable green - yellow colour.

-The input cable has to be located so that never reach the over temperature of 75 K.

-Please do not use in the connection any reduction, adaptation that may provoke a false contact with following dangerous overheatings.

When the connection has been done directly to the input system:

-Interpose between the appliance and the system an onnipolar switch, adequate to the load of the appliance, with a minimum nose between the contacts of 3 mm.

-Keep in mind that the " earth " cable does not have to be interrupted by the switch.

-In an alternative solution the electrical connection can also be protected by a differential switch with high sensitivity.

We recommend to fix the earth coloured cable to an appropriate earth installation.

WARNINGS:

All our products are projected and built according with the European Norms

EN 60 335-1 and EN 60 335-2-6 and relative amendments.

The appliance has been produced according with the European Directives:

-CEE 89/336 + 92/31 + 93/68 concerning the compatibility electromagnetic.

-CEE 73/23 + 93/68 concerning the electrical security.

4 HEATING ELEMENTS

1 or 2 HEATING ELEMENTS

FIG. 12

FIG. 13

25

Page 9
Image 9
Smeg SBC30 manual Electrical Connection, Installation