MAINTENANCE
Before doing any action, disconnect the appliance from the input power.
7) COMPONENTS SUBSTITUTION
To replace the components lodged in the internal part, is necessary to take the appliance up from the furniture, overturn it, loosen the screws and take away the bottom.
After these actions is possible to work on the plates, commutators, clamps and input cable.
In case of substitution of the input cable, the installer must keep the "earth" conductor longer
than "live" ones, and must respect the cautions in paragraph "ELECTRICAL CONNECTION".
To reassemble the appliance repeat the inverse process.
8)TECHNICAL CHARACTERISTICS OF THE ELECTRICALCOMPONENTS
To facilitate the job of the installer we present a scheme with the characteristics of the components.
POWER OF ELECTRICAL COMPONENTS
Denominations |
|
| W | |
Radiant electric heating element Ø 145 mm |
|
| 1200 | |
|
|
|
|
|
Radiant electric heating element Ø 145 mm |
|
| 1200 | |
|
|
|
|
|
Radiant electric heating element Ø 180 mm |
|
| 1700 | |
|
|
|
|
|
Radiant electric heating element Ø 180 mm |
|
| 1800 | |
|
|
|
|
|
Radiant electric heating element double cooking zone conc. Ø 180/120 mm | 1700 | |||
|
|
|
|
|
Radiant electric heating element double cooking zone oval 265/170 mm |
| 2200 | ||
|
|
|
|
|
Radiant electric heating element double cooking zone oval 265/170 mm |
| 2400 | ||
|
|
|
| |
Radiant electric heating element grill |
|
| 2200 | |
|
|
|
|
|
TYPE AND SECTION OF THE POWER CABLES (for 4 HEATING ELEMENTS) | ||||
|
|
|
|
|
Cable type | Single phase power | Three phase power | Three phase power | |
| monofase | Trifase | Trifase | |
| 230 - 240 V ~ | 400 – 415 V 3N ~ | 400 - 415 V 2N ~ | |
Rubber | 3 X 2.5 mm2 (*) | 5 X 1.5 mm2 (*) | 4 X 1.5 mm2 (*) | |
H05 | ||||
|
|
|
|
|
(*) keeping in mind the contemporaneousness factor
TYPE AND SECTION OF THE POWER CABLES (for 2 or 1 HEATING ELEMENTS)
Cable type | Single phase power |
| 230 - 240 V ~ |
|
|
Rubber | 3 X 1.5 mm2 (*) |
H05 | |
|
|
(*) keeping in mind the contemporaneousness factor
27