Smeg SC106ALU Instructions for the installer, Installing The Appliance, Electrical connection

Models: SC106 SC106ALU

1 29
Download 29 pages 5.19 Kb
Page 28
Image 28
Instructions for the installer

Instructions for the installer

13.INSTALLING THE APPLIANCE

13.1Electrical connection:

The nameplate with the technical data, serial number and mark is in a visible position on the oven door surround.

The nameplate must never be removed.

The appliance must be connected to earth in compliance with electrical system safety regulations.

If a permanent connection is used, the appliance's power supply line must be fitted with an omnipolar breaking device with contact gap of at least 3 mm, located in an easily accessible position close to the appliance itself.

If a socket and plug connection is used, check that they are of the same type. Do not use reducers, adapters or junctions since they may cause overheating or burns.

Operation at 220-240 V~: use a type H05RR-F (3 x 1.5 mm2) or type H05V2V2-F (3 x 1.5 mm2) three-wire cable.

The earth wire (yellow-green) must be at least 20 mm longer than the other wires at the end for connection to the appliance.

If the power supply lead has to be replaced, remove the rear casing by undoing the screws as shown below. The power lead gauge must be at

least 1.5 mm2 (3 X 1.5 cable) and it must withstand temperatures up to 90°C (H05V2V2-F). Make sure that the cables follow the best possible route and use band clamps to fix them at the side of the cabinet, to avoid any contact with the oven.

59

Page 28
Image 28
Smeg SC106ALU manual Instructions for the installer, Installing The Appliance, Electrical connection