17.FINAL OPERATIONS

Instructions for the installer

17.FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the appliance with the one corresponding to the new gas. This label is in the packet together with the nozzles.

17.1 Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position 17.1 Regulation of the hob burner minimum level for natural gas. Extract the gas tap knob and turn the adjustment screw inside or next (depending on the model) to the tap rod until the correct minimum flame is achieved.

Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to activate the safety device.

17.2 Mounting the rear top skirtboard (where applicable)

Loosen screws A located beneath the skirt.

Loosen nuts B.

Position the skirt above the top, taking care to align pins C with holes D.

Secure the skirt to the top by tightening screws E.